Voltage stabilizer thyristor NIK STV-12
Этого товара нет в наличии, заказ недоступен.
Stabilizer thyristor booster type NIK STV-12
STV stabilizers are used to limit the impact of voltage fluctuations on the operation of electricity consumers and provide:
equipment operation in a wide power supply range from 145 V to 275 V;
undistorted sinusoidal output voltage and work in the entire range of output loads (from idle to maximum load);
short circuit protection:
— electronic protection against impulse current — 2 ms;
— high quality circuit breaker;
protection against pulsed input voltage — over 275 V, response time 8 ms;
protection against undervoltage — 145 V, response time 100 ms;
work in the «transit» mode in an emergency;
motor protection
For the convenience of viewing the measurement data, a LCD display is installed on the front panel. The device is installed to improve the quality of power supply of apartments, houses, offices, industrial enterprises.
Model STV-12
nominal apparent power, kVA 12
rated input current, A 63
nominal input automat, A 63
number of stabilization stages 16
Efficiency with a load of 0.5 and an input voltage of 200 V,%, not less than 98
consumed active power at idle, W, not more than 20
input voltage measurement accuracy,% 1.5
rated output voltage, V 220 ± 10
output voltage adjustment value, V 8
stabilization range of input voltage at rated output voltage, V from 145 to 275
rated input voltage, V from 200 to 240
minimum operating voltage, V 145
minimum operating voltage, V 275
maximum readiness time at operating values of input voltage and temperature, s 10
reaction time to voltage drops, s, not more than 0.08
the time between lowering the input voltage below the minimum operating and disconnecting the load, with 0.2
the time between increasing the input voltage above the maximum operating voltage and turning off the stabilizer, s 0.1
the time between lowering the frequency below the minimum operating (40 Hz) and turning off the stabilizer, s 3
the time between raising the frequency above the maximum working (56 Hz) and turning off the stabilizer, from 3
degree of protection of the shell in accordance with GOST 14254-96 IP20
temperature at which compulsory cooling is activated, ° C 61
temperature at which mandatory cooling is turned off, ° С 35
input current at which mandatory cooling is activated, A, not less than 20
operating temperature range, ° C from 1 to 50
increased relative humidity of the environment at 30 ° С,% 93
weight 40 kg
dimensions (LxWxH), mm 384x182x522